UPDATED SOON.

NOPIG® PIPELINE INSPECTION SYSTEM
TECHNICAL SPECIFICATIONS

EU patent: EP 1075 658 B1 US patent: US 6 501 266 B1
US patent: US 6 727 695 B2

Nominal pipeline diameter

3” to 16”

Pipeline wall thickness1)

max. 10 mm

Depth of pipe (coverage)

max. 2 m

Pipeline inspection current

16 A eff

Length of inspection between

two contacting points

max. 1000 m

Inspection length per day2)

up to 750 m

Defect specifications ( POD > 96% ):

Length

min. 50 mm

Width

min. 50 mm

Peak depth

min. 50% of wall thickness

Defect detecting

> 20% metal loss

Depth resolution

≤ 20 mm

 

 